Guangdong ALI Testing Equipment Co,.Ltd

GSKA Group Specialized in kinds of PARTS since 1985, Developed and manufactured various generators and generator sets.

Manufacturer from China
Active Member
13 Years
Home / Products / Perkins Diesel Generator /

0.8 Power Factor Perkins Diesel Generator , 1103A-33TG2

Contact Now
Guangdong ALI Testing Equipment Co,.Ltd
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissKris
Contact Now

0.8 Power Factor Perkins Diesel Generator , 1103A-33TG2

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :GSKA
Model Number :JP-P65E3
MOQ :20-30 pieces
Price :Negotiable
Packaging Details :Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time :3-5 days on receipt of official sales contract
Payment Terms :L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability :500 pieces per Month
Port :HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion :CE/RoHs/ISO9001
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

1. Standby power: 52.0 KW

2.Engine Make & Model: Perkins 1103A-33TG2

3.Alternator Model: LL2014H

4.Circuit Breaker Type: 3 Pole MCB / 3 Pole MCCB

5.No. of Cylinders/Alignment: 3 / In Line

6.Cycle: 4 Stroke

7.Induction: Turbocharged

8.Cooling Method: Water Governing

9.Type: Mechanical Governing

10.Class: ISO 8528 G2

11.Compression Ratio: 17.25:1

12.Displacement: l (cu.in) 3.3 (201.4)

13.Bore/Stroke: mm (in) 105.0 (4.1)/127.0 (5.0)

0.8 Power Factor Perkins Diesel Generator , 1103A-33TG2

Output Ratings

Generating Set Model

* JPP65E3

Prime* Standby*

380-415V, 50 Hz

60.0 kVA 65.0 kVA

48.0 kW 52.0 kW

480V, 60 Hz

68.8 kVA 75.0 kVA

55.0 kW 60.0 kW

  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.

Technical Data

Engine Make & Model:

Perkins 1103A-33TG2

Alternator Model:

LL2014H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB / 3 Pole MCCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 1800

Fuel Tank Capacity: litres (US gal)

175 (46.2)

Fuel Consumption: P60P3 l/hr (US gal/hr)

13.8 (3.6) 15.9 (4.2)

Fuel Consumption: P65E3 l/hr (US gal/hr)

15.1 (4.0) 17.4 (4.6)

P60P3 / P65E3

Engine Technical Data

Physical Data

Manufacturer: Perkins

Model: 1103A-33TG2

No. of Cylinders/Alignment: 3 / In Line

Cycle: 4 Stroke

Induction: Turbocharged

Cooling Method: Water Governing

Type: Mechanical Governing

Class: ISO 8528 G2

Compression Ratio: 17.25:1

Displacement: l (cu.in) 3.3 (201.4)

Bore/Stroke: mm (in) 105.0 (4.1)/127.0 (5.0)

Moment of Inertia: kg m² (lb. in²) 1.14 (3896)

Engine Electrical System:

-Voltage/Ground: 12/Negative

-Battery Charger Amps: 65

Weight: kg (lb)

- Dry: 420 (926)

- Wet: 438 (966)

Air System 50 Hz 60 Hz

Air Filter Type:

Replaceable Element Combustion Air Flow: m³/min (cfm)

-Standby: 3.9 (138) 4.8 (170)

-Prime: 3.8 (134) 4.7 (166)

Max. Combustion Air Intake Restriction: kPa (in H2O) 8.0 (32.1) 8.0 (32.1)

Radiator Cooling Air Flow: m³/min (cfm) 110.4 (3899) 145.8 (5149)

External Restriction to Cooling Air Flow: Pa (in H2O) 120 (0.5) 120 (0.5)

Cooling System 50 Hz 60 Hz

Cooling System Capacity:l (US gal) 10.2 (2.7) 10.2 (2.7)

Water Pump Type: Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby: 37.7 (2144) 42.8 (2434)

-Prime: 35.2 (2002) 41.0 (2332)

Heat Radiation to Room: kW (Btu/min)

-Standby: 16.7 (950) 17.9 (1018)

-Prime: 15.2 (864) 17.0 (967)

Radiator Fan Load: kW (hp) 1.0 (1.3) 1.7 (2.3)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Performance 50 Hz 60 Hz

Engine Speed: RPM 1500 1800

Gross Engine Power: kW (hp)

-Standby: 60.5 (81.0) 69.6 (93.0)

-Prime: 55.0 (74.0) 63.3 (85.0)

BMEP: kPa (psi)

-Standby: 1467.0 (212.8) 1407.0 (204.0)

-Prime: 1333.0 (193.4) 1279.0 (185.5)

Regenerative Power: kW 7.0 9.0

LubriCAT-parts-partsion System

Oil Filter Type: Spin-On,

Full Flow Total Oil Capacity l (US gal): 8.3 (2.2)

Oil Pan l (US gal): 7.8 (2.1)

Oil Type: AP1 CG4 15W-40

Cooling Method: Water

Fuel System

Fuel Filter Type: Replaceable Element Recommended

Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110% 100% 75% 50%

Load Load Load Load

P60P3

50 Hz 15.1 (4.0) 13.8 (3.6) 10.3 (2.7) 7.3 (1.9)

60 Hz 17.4 (4.6) 15.9 (4.2) 12.0 (3.2) 8.8 (2.3)

P65E3

50 Hz 15.1 (4.0) 11.1 (2.9) 7.7 (2.0)

60 Hz 17.4 (4.6) 13.0 (3.4) 9.3 (2.5)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Exhaust System 50 Hz 60 Hz

Silencer Type: Level 1

Silencer Model & Qty: SD80 (1) Pressure Drop Across

Silencer System: kPa (in Hg) 0.98 (0.289) 1.22 (0.360)

Silencer Noise Reduction

Level: dB 19 18

Max. Allowable Back

Pressure: kPa (in. Hg) 15.0 (4.4) 15.0 (4.4)

Exhaust Gas Flow:

m³/min (cfm)

-Standby: 10.4 (367) 12.5 (441)

-Prime: 10.1 (357) 11.8 (417)

Exhaust Gas Temperature: °C (°F)

m³/min (cfm)

-Standby: 571 (1060) 564 (1047)

-Prime: 557 (1035) 534 (993)

P60P3 / P65E3

Alternator Performance Data

Data Item

50 Hz 60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V

Motor Starting Capability* kVA

148

139

128

164

163

109

127

119

140

Short Circuit Capacity** %

300

300

300

300

300

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

2.460

0.090

0.046

2.650

0.100

0.049

2.940

0.110

0.054

2.190

0.080

0.041

2.530

0.090

0.047

4.040

0.150

0.075

3.370

0.120

0.062

3.650

0.130

0.068

3.010

0.110

0.056

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

Alternator Technical Data

Physical Data Operating Data

Manufacturer: Jackpower

Overspeed: RPM 2250

Model: LL2014H

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz: 5.8 (330)

-60 Hz: 6.9 (392)

Excitation System: SHUNT

AVR Model: R230

P60P3 / P65E3

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

Voltage Prime Model Standby Model Voltage Prime Model Standby Model

P60P3 P65E3 P60P3 P65E3

kVA kW

kVA kW

kVA kW

kVA kW

415/240V

60.0 48.0

65.0 52.0

480/277V

68.8 55.0

75.0 60.0

400/230V

60.0 48.0

65.0 52.0

220/127V

68.8 55.0

75.0 60.0

380/220V

60.0 48.0

65.0 52.0

380/220V

68.7 55.0

75.0 60.0

230/115V

60.0 48.0

65.0 52.0

240/120V

68.8 55.0

75.0 60.0

220/127V

60.0 48.0

65.0 52.0

230/115V

68.8 55.0

75.0 60.0

220/110V

60.0 48.0

65.0 52.0

440/254V

68.8 55.0

75.0 60.0

200/115V

60.0 48.0

65.0 52.0

220/110V

68.7 55.0

75.0 60.0

208/120V

68.8 55.0

75.0 60.0

230/115V

68.8 55.0

75.0 60.0

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.



Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

0.8 Power Factor Perkins Diesel Generator , 1103A-33TG2

Weights and Dimensions

Weights: kg (lb) Dimensions: mm (in)

Net (+ lube oil)

944 (2081)

Length

2150 (84.6)

Wet (+ lube oil & coolant)

954 (2103)

Width

752 (29.6)

Fuel, lube oil & coolant

1099 (2423)

Height

1366 (53.8)

General Data

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


Warranty

All equipment carries full manufacturer's warranty.

Inquiry Cart 0