Add to Cart
1, Model :CCEC Cummins KTA19-G8, 4-cycle
2, Air Intake System :Turbo, Water/Air cooling
3, Fuel System :PT type fuel pump, EFC
4, Cylinder Arrangement : 6 in line
5, Standby Power:520KW / 650KVA
IP23 Air Cooling Cummins Diesel Genset , 520KW / 650KVA
Standby Power(50Hz) |
520KW / 650KVA |
Dimension & Weight
Standard Configuration (Open Type) |
Overall Size: 3500(mm)×1570(mm)×2050(mm) |
Weight: 4500kg |
General Features: |
Engine (CCEC Cummins KTA19-G8) |
Radiator 40OC max, fans are driven by belt, with safety guard |
24V charge alternator |
Alternator: single bearing alternator IP23, insulation class H/H |
Absorber |
Dry type air filter, double fuel filter, oil filter, coolant filter |
Main line circuit breaker |
Standard control panel |
Two12V batteries, rack and cable |
Ripple flex exhaust pipe, exhaust siphon, flange, muffler |
User manual |
Engine Data
Manufacturer / Model |
CCEC Cummins KTA19-G8, 4-cycle |
||||
Air Intake System |
Turbo, Water/Air cooling |
||||
Fuel System |
PT type fuel pump, EFC |
||||
Cylinder Arrangement |
6 in line |
||||
Displacement |
18.9 L |
||||
Bore and Stroke |
159*159(mm) |
||||
Compression Rate |
13.9 :1 |
||||
Rated RPM |
1500rpm |
||||
Max. Standby Power at Rated RPM |
575KW/782HP |
||||
Governor Type: |
Electronic |
||||
Exhaust System |
|||||
Exhaust Gas Flo |
1773L/s |
||||
Exhaust Temperature |
579℃ |
||||
Max Back Pressure |
10kPa |
||||
Air Intake System |
|||||
Max Intake Restriction |
6.23kPa |
||||
Consumption |
635L/s |
||||
Air Flow |
10800L/s |
||||
Fuel System |
|||||
100%(Standby Power) Loa |
205 g/Kw |
||||
75%( Standby Power) Load: |
205 g/Kw |
||||
50%( Standby Power) Loa |
211 g/Kw.h |
||||
100%(Standby Power) Loa |
132.2L/h |
||||
Oil System |
|||||
Total Oil Capacity |
50L |
||||
Oil Consumption |
≤4g/kwh |
||||
Engine Oil Tank Capacity |
38L |
||||
Oil Pressure at Rated RPM |
345-483kPa |
||||
Cooling System |
|||||
Total Coolant Capacity |
116.5L |
||||
Thermostat: |
82-93℃ |
||||
Max Water Temperature |
104℃ |
Alternator SpecifiCAT-parts-partsion
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
Number of Phase: |
3 |
Connecting Type: |
3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: |
1 |
Power Factor: |
0.8 |
Protection Grade: |
IP23 |
Altitude: |
≤1000m |
Exciter Type: |
Brushless, self-exciting |
Insulation Class, Temperature Rise: |
H/H |
Telephone Influence Factor (TIF): |
<50 |
THF: |
<2% |
Voltage Regulation, Steady State: |
≤±1% |
Alternator Capacity: |
625KVA |
Alternator Efficiencies: |
95.1% |
Air Cooling Flow: |
1.035m3/s |
Generating set data:
Voltage Regulation: |
≥±5% |
Voltage Regulation, Stead State: |
≤±1% |
Sudden Voltage Warp (100% Sudden Reduce): |
≤+25% |
Sudden Voltage Warp (Sudden Increase): |
≤-20% |
Voltage Stable Time (100% Sudden Reduce): |
≤6S |
Voltage Stable Time (Sudden Increase) |
≤6S |
Frequency Regulation, Stead State: |
≤5% |
Frequency Waving: |
≤0.5% |
Sudden Frequency Warp (100% Sudden Reduce): |
≤+12% |
Sudden Frequency Warp (Sudden Increase): |
≤-10% |
Frequency Recovery Time (100% Sudden Reduce): |
≤5S |
Frequency Recovery Time (Sudden Increase): |
≤5S |
Competitive Advantage:
High Performance of loading Easy start
Nice protection User-friendly operation
Low running cost Environmental Long service life