Add to Cart
High Frequency Backup Power Supply Online UPS 6k To 12v Ups Power Supply
Feature:
 * Double conversion
 * Microprocessor optimizes reliability
 * Input power factor correction
 * Output power factor 0.8
 * Wide input voltage range
 * Compatible generator
 * The charging current of the long-acting machine can be extended up to 6A
|  			 Model  			 |  			 			 GSKA-500  			 |  			 			 GSKA-800  			 |  			 			 GSKA-1000  			 |  			 			 GSKA-1500  			 |  			 			 GSKA-2000  			 |  			 			 GSKA-2500  			 |  			 			 GSKA-3000  			 |  			 			 GSKA-5000  			 |  		|
|  			 Rated Capacity  			 |  			 			 500VA  			 |  			 			 800VA  			 |  			 			 1000VA  			 |  			 			 1500VA  			 |  			 			 2000VA  			 |  			 			 2500VA  			 |  			 			 3000VA  			 |  			 			 5000VA  			 |  		|
|  			 Rated Power  			 |  			 			 300W  			 |  			 			 500W  			 |  			 			 700W  			 |  			 			 1050W  			 |  			 			 1400W  			 |  			 			 1800W  			 |  			 			 2100W  			 |  			 			 3500W  			 |  		|
|  			 Transformer  			 |  			 			 Toroidal transformer  			 |  		||||||||
|  			 Interface  			 |  			 			 LED graphic  			 |  		||||||||
|  			 Display status  			 |  			 			 working&loading&battery  			 |  		||||||||
|  			 Working mode  			 |  			 			 PV(Photovoltaic priority)/AC(AC priority) optional  			 |  		||||||||
|  			 Input  			 |  			 			 Voltage  			 |  			 			 140-275Vac  			 |  		|||||||
|  			 Frequency  			 |  			 			 45-65Hz  			 |  		||||||||
|  			 Output  			 |  			 			 Voltage  			 |  			 			 220Vac±3% for inveter; 195v-240V for avr  			 |  		|||||||
|  			 Frequency  			 |  			 			 50/60Hz ± 0.3Hz, subject to the main  			 |  		||||||||
|  			 Wave Form  			 |  			 			 Pure sine wave  			 |  		||||||||
|  			 Wave Distortion  			 |  			 			 ≤3%  			 |  		||||||||
|  			 Protection  			 |  			 			 overload/high temperature/output high voltage /output low voltage/  			battery low voltage shortcircuit/over-charge/over-discharge/reversed polarity(optional)  |  		||||||||
|  			 Transfer Time  			 |  			 			 ≤4ms  			 |  		||||||||
|  			 Battery Voltage  			 |  			 			 12VDC  			 |  			 			 24VDC  			 |  			 			 48VDC  			 |  		||||||
|  			 Charge Voltage  			 |  			 			 13.6V±0.3V  			 |  			 			 27.2V±0.6V  			 |  			 			 54.5V±1V  			 |  		||||||
|  			 Low Battery Voltage Limit  			 |  			 			 10.9V±0.3V  			 |  			 			 21.8V±0.5V  			 |  			 			 42V±1V  			 |  		||||||
|  			 Protections Battery Low Voltage Protection Point  			 |  			 			 10.2V±0.3V  			 |  			 			 20.5V+0.5V  			 |  			 			 41V±1V  			 |  		||||||
|  			 Charge Current  			 |  			 			 Max.10A/15A/20A optional  			 |  		||||||||
|  			 Environmental  			 |  			 			 Operating Temperature  			 |  			 			 0~40℃  			 |  		|||||||
|  			 Relative Humidity  			 |  			 			 10%~90%RH,non-condensing  			 |  		||||||||
|  			 Storage Temperature  			 |  			 			 -15-45℃  			 |  		||||||||
|  			 Packing  			 |  			 			 Machine Size(mm)  			 |  			 			 280x144x213  			 |  			 			 385x190x320  			 |  		||||||
|  			 Qty/Ctn  			 |  			 			 4  			 |  			 			 4  			 |  			 			 2  			 |  			 			 2  			 |  			 			 1  			 |  			 			 1  			 |  			 			 1  			 |  			 			 1  			 |  		|
|  			 Carton Size(mm)  			 |  			 			 785x305x240  			 |  			 			 415x410x245  			 |  			 			 410x290x320  			 |  		||||||
|  			 CartonG.W.(kg)  			 |  			 			 22  			 |  			 			 26  			 |  			 			 17.2  			 |  			 			 19.1  			 |  			 			 410x290x321  			 |  		||||