
Add to Cart
Convenient Portable Compact Diesel Generator Super Quiet Electric Start OEM
Mode of operation:
One or more diesel generators that operate without being connected to the grid is called island operation mode. Working generators in parallel can achieve better efficiency under partial load. An isolated plant for the main power supply of an isolated community will typically have at least three diesel generators, any two of which are rated to carry the required load.
Generators can be electrically connected by a synchronization process. Synchronization involves matching voltage, frequency and phase before connecting the generator to the system. Failure to synchronize prior to connection may result in high short-circuit currents or wear on the generator or its switchgear. The synchronization process can be done automatically by an automatic synchronization module or manually by a guided operator. The automatic synchronizer will read the voltage, frequency and phase parameters from the generator and bus voltage while adjusting the speed via the engine governor or ECM (engine control module).
Loads can be shared between generators operating in parallel through load sharing. Load sharing can be achieved by using a descent rate control controlled by the generator frequency, while it continuously adjusts the engine fuel control to transfer the load to or from the residual power supply. The diesel generator will take on more of the load as the fuel supply to its combustion system increases, while releasing the load if the fuel supply decreases.
Standard unit unit:
The standard unit is widely used in the general place of installation in the machine room. The unit is mainly composed of diesel engine, generator, control system, frame, damping device, cooling system, oil supply system, and output protection switch and other parts.
Protective type unit:
Protective units are used in outdoor places where there is no special requirement for noise. It is mainly composed of standard unit, protective cover shell and smoke exhaust system. Since there is no noise reduction device in the protective cover shell, as long as it meets the conditions of ventilation and rain and snow protection, it has a smaller shape and a lower cost. Open doors and Windows for ventilation when the unit is running. The protective power station can be used in parallel with single or multiple sets. The multi-set parallel operation is especially suitable for the occasions with large load changes, high reliability requirements for continuous operation and low cost and economic use, such as supporting oilfield drilling RIGS.
Model | GSKA7500 | |
ALTERNATOR | Frequency (HZ) | 50/60HZ |
Max.output (KW) | 5/5.5 | |
Rated output(KW) | 4/6.5 | |
Rated AC Voltage(V) | 220V; 230V; 127V | |
Power Factor | 1 | |
DC output (V) | 12V/8.3A | |
Phase | Single phase | |
Alternator Type | Self-excited,2-pole, Single alternator | |
Starting System | Electric | |
Noise Level(Dba/7m) | 80-85Db | |
Fuel Tank Capacity (L) | 12.5 | |
Continuous Running Time (hr) | 6.5/6 | |
ENGINE | Engine Model | 168FA |
Engine Type | single-cylinder, vertical,4-stroke air-cooled diesel engine | |
Bore×Stroke (mm) | 86×72 | |
Fuel Consumption rate (g/kw/h) | ≤280 | |
Fuel | 0# or -10# light diesel oil | |
LubriCAT-parts-partsion Oil Volume (L) | 1.65 | |
Combustion System | Direct Injection | |
CONTROL PANEL | Voltmeter | YES |
AC Output Socket | 2 | |
AC Circuit Breaker | YES | |
Oil warning Light | YES | |
Oil Alert | YES | |
DIMENSIONS | Dimention(LxWxH)(mm) | 735*495*610 |
Net Weight(kgs) | 102 | |
20FT装载件 | 50 |