Add to Cart
Silent Electric Generator Set Portable Silent Diesel Generator 3KW-1000KW
Protective type unit:
Protective units are used in outdoor places without special requirements for noise. It is mainly composed of standard unit, protective cover shell, smoke exhaust system and so on. Since the protective cover shell is not set with noise reduction device, as long as it meets the conditions of ventilation and rain and snow prevention, it has a smaller shape volume and a lower cost. Open doors and Windows for ventilation when the unit is in operation. The protective power station can be used in single or multiple parallel connections. The parallel connection of multiple power stations is especially suitable for the occasions where the load varies greatly, the continuous operation reliability is required and the low cost is used economically, such as supporting oil RIGS.
parameter:
Size and type selection - typical load of electrical equipment, expected load of appliCAT-parts-partsion
Electrical factors - Peak load with stability, allowed for appliCAT-parts-partsion
Cooling - Engine cooling during power generation
Ventilation - Airflow allowed during cooling (design)
Fuel storage - How long a generator runs at a specific rate of use
Noise-db levels for specific models
Exhaust - ppm (parts per million) of certain elements, considering the environment and the environment around the generator
Start the system - key start, pull start, button start, etc
Engine Data:
Manufacturer / Model: | DCEC Cummins 6CTA8.3-G2, 4-cycle |
Air Intake System: | Turbo, Water/Air Cooling |
Fuel System: | PB/W type fuel pump |
Cylinder Arrangement: | 6 in line |
Displacement: | 8.3L |
Bore and Stroke: | 114*135(mm) |
Compression Ratio: | 17:1 |
Rated RPM: | 1500rpm |
Max. Standby Power at Rated RPM: | 180KW/244HP |
Governor Type: | Electronic |
Exhaust System | |
Exhaust Gas Flow: | 34.7m3/min |
Exhaust Temperature: | 570℃ |
Max Back Pressure: | 10kPa |
Air Intake System | |
Max Intake Restriction: | 6kPa |
Burning Capacity: | 12.4m3/min |
Air Flow: | 238m3/min |
Fuel System | |
100%( Prime Power) Load: | 215 g/Kw.h |
75%(Prime Power) Load: | 211 g/Kw.h |
50%(Prime Power) Load:: | 216 g/Kw.h |
100%( Prime Power) Load: | 39.7L /h |
Oil System | |
Total Oil Capacity: | 23.8L |
Oil Consumption: | ≤4g/kwh |
Engine Oil Tank Capacity: | 18.9L |
Oil Pressure at Rated RPM: | 276-414kPa |
Cooling System | |
Total Coolant Capacity: | 34L |
Thermostat: | 82-95℃ |
Max Water Temperature: | 104℃ |
Alternator SpecifiCAT-parts-partsion:
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data:
Alternator Data | |
Number of Phase: | 3 |
Connecting Type: | 3 Phase and 4 Wires, “Y” type connecting |
Number of Bearing: | 1 |
Power Factor: | 0.8 |
Protection Grade: | IP23 |
Altitude: | ≤1000m |
Exciter Type: | Brushless, self-exciting |
Insulation Class, Temperature Rise: | H/H |
Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | ≤±1% |
Alternator Capacity: | 182KVA |
Alternator Efficiencies: | 92.4% |
Air Cooling Flow: | 0.514m3/s |