1, Standby Power:550KW / 688KVA
2, Standard Configuration: Open Type
3, Model : CCEC Cummins KTAA19-G6A
4, Air Intake System:Turbo, Water/Air cooling
5, Fuel System:PT type fuel pump, EFC
6, Cylinder Arrangement:6 in line
50Hz 6 Cylinder Cummins Diesel Generators , KTAA19-G6A
|
Standby Power(50Hz) |
550KW / 688KVA |
|
Prime Power(50Hz) |
NA |
Dimension & Weight
|
Standard Configuration (Open Type) |
|
Overall Size: 3700(mm)×1570(mm)×2080(mm) |
|
Weight: 4550kg |
|
General Features: |
|
Engine (CCEC Cummins KTAA19-G6A) |
|
Radiator 40OC max, fans are driven by belt, with safety guard |
|
24V charge alternator |
|
Alternator: single bearing alternator IP23, insulation class H/H |
|
Absorber |
|
Dry type air filter, double fuel filter, oil filter, coolant filter |
|
Main line circuit breaker |
|
Standard control panel |
|
Two12V batteries, rack and cable |
|
Ripple flex exhaust pipe, exhaust siphon, flange, muffler |
|
User manual |
Engine Data
|
Manufacturer / Model |
CCEC Cummins KTA19-G6A, 4-cycle |
|||
|
Air Intake System |
Turbo, Water/Air cooling |
|||
|
Fuel System |
PT type fuel pump, EFC |
|||
|
Cylinder Arrangement |
6 in line |
|||
|
Displacement |
18.9 L |
|||
|
Bore and Stroke |
159*159(mm) |
|||
|
Compression Rat |
13 :1 |
|||
|
Rated RPM |
1500rpm |
|||
|
Max. Standby Power at Rated RPM |
610KW/830HP |
|||
|
Governor Type: |
Electronic |
|||
|
Exhaust System |
||||
|
Exhaust Gas Flow |
2054L/S |
|||
|
Exhaust Temperature |
584℃ |
|||
|
Max Back Pressure |
10kPa |
|||
|
Air Intake System |
||||
|
Max Intake Restriction |
6.23kP |
|||
|
Consumption |
750L/S |
|||
|
Air Flow |
10800 L/S |
|||
|
Fuel System |
||||
|
100%( Standby Power) Load |
206 g/K.wh |
|||
|
75%( Standby Power) Load: |
205 g/K.wh |
|||
|
50%( Standby Power) Load |
206 g/K.wh |
|||
|
100%( Standby Power) Loa |
140.2L/h |
|||
|
Cooling System |
||||
|
Total Coolant Capacity |
116.5L |
|||
|
Thermostat: |
82-93℃ |
|||
|
Max Water Temperature |
104℃ |
|||
Alternator SpecifiCAT-parts-partsion
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
|
Number of Phase: |
3 |
|
Connecting Type: |
3 Phase and 4 Wires, “Y” type connecting |
|
Number of Bearing: |
1 |
|
Power Factor: |
0.8 |
|
Protection Grade: |
IP23 |
|
Altitude: |
≤1000m |
|
Exciter Type: |
Brushless, self-exciting |
|
Insulation Class, Temperature Rise: |
H/H |
|
Telephone Influence Factor (TIF): |
<50 |
|
THF: |
<2% |
|
Voltage Regulation, Steady State: |
≤±1% |
|
Alternator Capacity: |
625KVA |
|
Alternator Efficiencies: |
95.1% |
|
Air Cooling Flow: |
1.035m3/s |
Generating set data:
|
Voltage Regulation: |
≥±5% |
|
Voltage Regulation, Stead State: |
≤±1% |
|
Sudden Voltage Warp (100% Sudden Reduce): |
≤+25% |
|
Sudden Voltage Warp (Sudden Increase): |
≤-20% |
|
Voltage Stable Time (100% Sudden Reduce): |
≤6S |
|
Voltage Stable Time (Sudden Increase) |
≤6S |
|
Frequency Reduce: |
≤5% |
|
Frequency Regulation, Stead State: |
≤1.5% |
|
Frequency Waving: |
≤0.5% |
|
Sudden Frequency Warp (100% Sudden Reduce): |
≤+12% |
|
Sudden Frequency Warp (Sudden Increase): |
≤-10% |
|
Frequency Recovery Time (100% Sudden Reduce): |
≤5S |
|
Frequency Recovery Time (Sudden Increase): |
≤5S |
|
|
|
Options
Competitive Advantage:
High Performance of loading Easy start
Nice protection User-friendly operation